EJNMMI Phys ; 10(1): 73, 2023 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-37993667

RESUMO

INTRODUCTION: Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging. MATERIALS AND METHODS: Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68-107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I. RESULTS: As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12-1.5%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction. CONCLUSION: This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals.

2.
Appl Radiat Isot ; 200: 110947, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37467537

RESUMO

A bilateral comparison to determine the activity concentration of the same 125I solution was organized. As electron-capture radionuclide with a rather high atomic number, 125I must be regarded as difficult to measure. The situation is partly exacerbated by the fact that some established standardization methods, like photon-photon coincidence counting, can no longer be applied due to the unavailability of appropriate equipment and expertise. One aim of this work is to compare modern liquid scintillation counting methods for the standardization of 125I. Both participating metrology institutes have used their custom-built triple-to-double-coincidence ratio (TDCR) counters and the determined activity concentrations are in excellent agreement even though the ways to analyze the data and to compute counting efficiencies were widely independent. The results also agree with the outcome of 4π-γ counting that was carried out at LNHB. In both laboratories, the measurements were complemented by measurements with several secondary standardization methods which even allow to establish a link to the CCRI(II)-K2.I-125(2) comparison started in 2004. A good agreement between the TDCR results and the key comparison reference value of the 2004/2005 comparison was obtained.

3.
Appl Radiat Isot ; 154: 108886, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31539710

RESUMO

PENELOPE simulations of a Vinten ionization chamber (IC) were performed to investigate the influence of the thickness of glass-ampoules used in 222Rn standardization. The simulation reveals a non-negligible variation of the energy deposited in the chamber gas region (which may induce a proportional variation of the measured current) when considering the ß transition emissions of the daughters of 222Rn. This reinforces the idea of using a specialist container (made of metal to preserve the integrity of the container) that would circulate between the metrology laboratories in the context of international comparison exercises using the BIPM international reference system (SIR).

4.
Appl Radiat Isot ; 109: 154-159, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26651173

RESUMO

The activity per unit mass of an iodine-131 solution was absolutely standardized by both the 4πß-γ coincidence method and the 4πγ counting technique. The calibrated solution was used to prepare point sources after a preliminary deposit of AgNO3 to prevent the loss of volatile iodine. Relative and absolute photon emission intensities of 15 sgamma-rays and those of the two K X-rays of xenon were determined by gamma-ray spectrometry, with relative uncertainties of 0.8% for the three main emissions.